Delta UPS – Amplon Family
RT Series, Single Phase
Reliable power with intelligent energy-saving features
The Amplon RT series delivers double-conversion on-line technology, high power density and input power factor, and low current harmonics with its advanced architecture. Designed in a
rack or tower configuration with an LCD display, Amplon RT offers advanced performance for servers, data centers, networking, VoIP and telecommunications.
The Amplon RT has 1+1 parallel redundancy function to provide higher reliability. Optional external battery pack can be added to fulfill longer backup time for mission critical applications.
Availability
• True online double-conversion topology provides 24/7 full-time protection.
• 1+1 parallel redundancy or expansion without requiring additional hardware.
• AC-start and battery-start capabilities.
• Additional charger board can be added to reduce recharging time.
• Optional maintenance bypass box for parallel redundancy with manual bypass switch.
• External charger box enhances battery charging ability.
Flexibility
• Rack or tower configuration.
• Multi-language LCD display with blue backlight.
• Optional external battery pack for longer backup time.
Low Total Cost Of Ownership
• Output factor 0.9 delivers more real power.
• High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 5%).
• Common battery installation enables two UPS in parallel to share one battery source for cost savings.
• Wide input voltage range reduces battery discharging occurrence and prolongs battery lifetime.
Model - RT-6K
Power Rating - 6kVA/5.4kW
Input
Nominal Voltage - 200/208/220/230/240 Vac (single phase)
Voltage Range - 100 ~ 300 Vac*
Current Harmonic Distortion - < 5% (full load)
Power Factor - > 0.99 (full load)
Frequency - 40 ~ 70 Hz
Electrical Connection - Terminal block
Output
Voltage - 200/208/220/230(default)/240 Vac (single phase)
Voltage Harmonic Distortion - < 2% (linear load)
Voltage Regulation - ± 1% (static); ± 2% (typical)
Frequency - 50 or 60 ± 0.05 Hz
Overload Capability - 106 ~ 110%: 10 minutes; 111 ~ 125%: 5 minutes; 126 ~ 150%: 30 seconds
Electrical Connection - Terminal block
Crest Factor - 3:1
Battery & Charger
Included batteries - 16pcs. 12V/7Ah
Nominal Voltage - 192 Vdc
Charge Current - Built-in: maximum 4A (adjustable); Additional charger board (optional): maximum 4A (internal installation)
Electrical Connection - Exclusive cable
Interface
Standard - RS232 x 1, SNMP slot x 1, Smart slot x 1, Parallel port x 1
Conformance
Safety & EMC - CE, TUV, EN62040-1; CISPR 22 Class A
Others Features
Parallel Redundancy - 1+1
Remote Control - REPO; Remote On/Off
Common Battery Installation - Yes
Efficiency
AC-AC - 92% (full load)
ECO Mode - 96% (full load)
Environment
Operating Temperature - 0 ~ 40ºC
Relative Humidity - 0 ~ 95% (non-condensing)
Audible Noise - 54 dBA (at 70% load)
Physical
Dimensions (WxDxH):
UPS - 440 x 671 x 89 mm
Battery Pack - 440 x 638 x 89 mm
Weight:
UPS - 15.5 kg
Battery Pack - 36 kg
* Lower range 100 ~ 155 Vac is acceptable under 50 ~ 100% loading condition.
Виж още UPS Artronic
Виж всички UPS в категорията
RT Series, Single Phase
Reliable power with intelligent energy-saving features
The Amplon RT series delivers double-conversion on-line technology, high power density and input power factor, and low current harmonics with its advanced architecture. Designed in a
rack or tower configuration with an LCD display, Amplon RT offers advanced performance for servers, data centers, networking, VoIP and telecommunications.
The Amplon RT has 1+1 parallel redundancy function to provide higher reliability. Optional external battery pack can be added to fulfill longer backup time for mission critical applications.
Availability
• True online double-conversion topology provides 24/7 full-time protection.
• 1+1 parallel redundancy or expansion without requiring additional hardware.
• AC-start and battery-start capabilities.
• Additional charger board can be added to reduce recharging time.
• Optional maintenance bypass box for parallel redundancy with manual bypass switch.
• External charger box enhances battery charging ability.
Flexibility
• Rack or tower configuration.
• Multi-language LCD display with blue backlight.
• Optional external battery pack for longer backup time.
Low Total Cost Of Ownership
• Output factor 0.9 delivers more real power.
• High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 5%).
• Common battery installation enables two UPS in parallel to share one battery source for cost savings.
• Wide input voltage range reduces battery discharging occurrence and prolongs battery lifetime.
Model - RT-6K
Power Rating - 6kVA/5.4kW
Input
Nominal Voltage - 200/208/220/230/240 Vac (single phase)
Voltage Range - 100 ~ 300 Vac*
Current Harmonic Distortion - < 5% (full load)
Power Factor - > 0.99 (full load)
Frequency - 40 ~ 70 Hz
Electrical Connection - Terminal block
Output
Voltage - 200/208/220/230(default)/240 Vac (single phase)
Voltage Harmonic Distortion - < 2% (linear load)
Voltage Regulation - ± 1% (static); ± 2% (typical)
Frequency - 50 or 60 ± 0.05 Hz
Overload Capability - 106 ~ 110%: 10 minutes; 111 ~ 125%: 5 minutes; 126 ~ 150%: 30 seconds
Electrical Connection - Terminal block
Crest Factor - 3:1
Battery & Charger
Included batteries - 16pcs. 12V/7Ah
Nominal Voltage - 192 Vdc
Charge Current - Built-in: maximum 4A (adjustable); Additional charger board (optional): maximum 4A (internal installation)
Electrical Connection - Exclusive cable
Interface
Standard - RS232 x 1, SNMP slot x 1, Smart slot x 1, Parallel port x 1
Conformance
Safety & EMC - CE, TUV, EN62040-1; CISPR 22 Class A
Others Features
Parallel Redundancy - 1+1
Remote Control - REPO; Remote On/Off
Common Battery Installation - Yes
Efficiency
AC-AC - 92% (full load)
ECO Mode - 96% (full load)
Environment
Operating Temperature - 0 ~ 40ºC
Relative Humidity - 0 ~ 95% (non-condensing)
Audible Noise - 54 dBA (at 70% load)
Physical
Dimensions (WxDxH):
UPS - 440 x 671 x 89 mm
Battery Pack - 440 x 638 x 89 mm
Weight:
UPS - 15.5 kg
Battery Pack - 36 kg
* Lower range 100 ~ 155 Vac is acceptable under 50 ~ 100% loading condition.
Виж още UPS Artronic
Виж всички UPS в категорията
Технически характеристики
Изходяща мощност: | 6000 VA |
---|---|
Тип: | ON Line |
Формфактор: | Rack/Tower |
Добави Ревю / Въпрос
Оцени продукта или задай въпрос?
- 5
- 4
- 3
- 2
- 1
Свързани продукти