ARTon Titanium Plus RM Series
19"" Rack Mount 1-2-3 kVA
- VFI Topology Class 1, Double Conversion UPS
- DSP Controlled Maximum Reliability
- Wide Input Voltage Range (110~300 VAC)
- Green Energy with Input Power Factor Correction (PFC)
- Graphic LCD Display and Touchpad Control Keys
- Automatic Restart & Cold Start Function
- Network Supported Monitoring & Control Software
- SNMP & AS400 Network Monitoring Options
- Silent & Economic Operation with Variable Fan Speed
Capacity (VA/Watt) - 1000 VA / 800 Watt
Input - Rectifier
Voltage-Voltage Tolerance - 220 VAC, 1 Phase + Neutral, 110 ~ 300 VAC
Voltage Tolerance According to Load % - Transfer to battery at 110 VAC for 0~60% load, 120 VAC for 61~70% load, 140 VAC for 71~80 load, 160 VAC for 81~100% load (Tolerance +/- 5V); Transfer to battery at 300 VAC for 0~100% load, transfer back to the mains at 285 VAC for 0~100% load
Power Factor - >= 0.99
Current (maximum) - 12A
Total Harmonic Distortion - < 5%
Frequency - 45~55 Hz
Output - Inverter & Bypass
Power Factor - 0.8
Voltage-Voltage Tolerance - 220 VAC +/- 2%
Frequency-Frequency Tolerance - 50 Hz, +/- 0.2 Hz for Battery Operation
Voltage Waveform - Pure Sine Wave
Total Harmonic Distortion - <= 3% at linear load
Crest Factor - 3:1
Overload Capacity - 60 seconds for 105% ~ 110%, 30 seconds for 111% ~ 125%, 10 seconds for 126% ~ 150%, 1 second for 150%
Short Circuit Protection - Electronic Short Circuit Protection
Bypass & Transfer Time - Standard Static Bypass, 0 (zero) for Line Mode to Battery Mode, <4 miliseconds for Inverter to Bypass or Eco Mode
Bypass Tolerance & Adjustment - 80~286 VAC Adjustable, Bypass can be Disable or Enable to Use in Standby Mode
Battery
Type & Placement - Maintenance Free Dry Type Battery, Internal or External Regarding to Demand
Capacity & Quantity - 12V 7Ah x 8 pieces
Bacup Time (100% SMPS Load) - 6 minutes
Float Charge Voltage - 110 +/- 0.4 VDC
End of Discharge Voltage - 80 VDC
Battery Charge Current & Charge Time - Standard 1 Amper Charge Current, 5 hours Charge Time to 90% Capacity After Discharge, Optional High Capacity Charger for Long Backup Demand
Indications & Control Panel
Type - Graphic LCD Panel
Control Panel - Touchpad Buttons (On/off, Audible Alarm Disable, Up/Down, Enter)
Measurements & Warnings - UPS Status, Input/Output Voltage & Frequency, Load %, Battery Capacity & Voltage, Warning & Alarm Messages
Indications (LCD) - Mimic Diagram for Energy Flow, Measurements, Warnings, Faults, Adjustments ECO Mode, Converter Mode
Protections
Over Load - 60sn at 105%~110% Load, 30sn at 111%~125% Load, 10sn at 126%~150% Load, 1sn at 150% Load Transfer to Bypass Without Any Break After Over Load Period
Short Circuit - Automatic Inverter Shutdown
Over Temperature - Load Transfer to Bypass for 90C Internal Temperature, Transfer Back to Inverter When Internal Temperature <80C
Audible Warnings
Warning Type and Warnings - Buzzer, Mutable with Audible Alarm Disable; Different Audible Signals for Battery Operation, Battery Low Voltage, UPS Fault, Over Load
Communications
Interface & Protocol - Smart RS232 Communication with DV9 Port, Optional SNMP or AS 400 Support, EPO Input Terminal
Software - Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98 / ME / NT / 2000 / XP / 2003, Linux, Sun Solaris 7 / 8 / 9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported
General
Efficiency - AC to AC at 100% / at ECO Mode - 88% / 95%
Noise Level - < 50 dBA
Electro Magnetic Compatibility - EN 62040-1, EN 62040-2, 62040-3, EN 60950-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5
Operating Temperature & Humidity - 0C~45C, Maximum 20~90% (Non Condensed)
Storage Temperature - -20C~70C
Protection Class - IP 20
Cooling Type - Forced Cooling Fan with Adjusted Speed
Operating Altitude - < 1000 meters (from Sea Level)
Dimensions (mm), W x H x D - 483 x 88 (2U) x 450
Weight, without / with Battery (kg) - 11.2 + 25.3
Виж още UPS Artronic
Виж всички UPS в категорията
19"" Rack Mount 1-2-3 kVA
- VFI Topology Class 1, Double Conversion UPS
- DSP Controlled Maximum Reliability
- Wide Input Voltage Range (110~300 VAC)
- Green Energy with Input Power Factor Correction (PFC)
- Graphic LCD Display and Touchpad Control Keys
- Automatic Restart & Cold Start Function
- Network Supported Monitoring & Control Software
- SNMP & AS400 Network Monitoring Options
- Silent & Economic Operation with Variable Fan Speed
Capacity (VA/Watt) - 1000 VA / 800 Watt
Input - Rectifier
Voltage-Voltage Tolerance - 220 VAC, 1 Phase + Neutral, 110 ~ 300 VAC
Voltage Tolerance According to Load % - Transfer to battery at 110 VAC for 0~60% load, 120 VAC for 61~70% load, 140 VAC for 71~80 load, 160 VAC for 81~100% load (Tolerance +/- 5V); Transfer to battery at 300 VAC for 0~100% load, transfer back to the mains at 285 VAC for 0~100% load
Power Factor - >= 0.99
Current (maximum) - 12A
Total Harmonic Distortion - < 5%
Frequency - 45~55 Hz
Output - Inverter & Bypass
Power Factor - 0.8
Voltage-Voltage Tolerance - 220 VAC +/- 2%
Frequency-Frequency Tolerance - 50 Hz, +/- 0.2 Hz for Battery Operation
Voltage Waveform - Pure Sine Wave
Total Harmonic Distortion - <= 3% at linear load
Crest Factor - 3:1
Overload Capacity - 60 seconds for 105% ~ 110%, 30 seconds for 111% ~ 125%, 10 seconds for 126% ~ 150%, 1 second for 150%
Short Circuit Protection - Electronic Short Circuit Protection
Bypass & Transfer Time - Standard Static Bypass, 0 (zero) for Line Mode to Battery Mode, <4 miliseconds for Inverter to Bypass or Eco Mode
Bypass Tolerance & Adjustment - 80~286 VAC Adjustable, Bypass can be Disable or Enable to Use in Standby Mode
Battery
Type & Placement - Maintenance Free Dry Type Battery, Internal or External Regarding to Demand
Capacity & Quantity - 12V 7Ah x 8 pieces
Bacup Time (100% SMPS Load) - 6 minutes
Float Charge Voltage - 110 +/- 0.4 VDC
End of Discharge Voltage - 80 VDC
Battery Charge Current & Charge Time - Standard 1 Amper Charge Current, 5 hours Charge Time to 90% Capacity After Discharge, Optional High Capacity Charger for Long Backup Demand
Indications & Control Panel
Type - Graphic LCD Panel
Control Panel - Touchpad Buttons (On/off, Audible Alarm Disable, Up/Down, Enter)
Measurements & Warnings - UPS Status, Input/Output Voltage & Frequency, Load %, Battery Capacity & Voltage, Warning & Alarm Messages
Indications (LCD) - Mimic Diagram for Energy Flow, Measurements, Warnings, Faults, Adjustments ECO Mode, Converter Mode
Protections
Over Load - 60sn at 105%~110% Load, 30sn at 111%~125% Load, 10sn at 126%~150% Load, 1sn at 150% Load Transfer to Bypass Without Any Break After Over Load Period
Short Circuit - Automatic Inverter Shutdown
Over Temperature - Load Transfer to Bypass for 90C Internal Temperature, Transfer Back to Inverter When Internal Temperature <80C
Audible Warnings
Warning Type and Warnings - Buzzer, Mutable with Audible Alarm Disable; Different Audible Signals for Battery Operation, Battery Low Voltage, UPS Fault, Over Load
Communications
Interface & Protocol - Smart RS232 Communication with DV9 Port, Optional SNMP or AS 400 Support, EPO Input Terminal
Software - Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98 / ME / NT / 2000 / XP / 2003, Linux, Sun Solaris 7 / 8 / 9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported
General
Efficiency - AC to AC at 100% / at ECO Mode - 88% / 95%
Noise Level - < 50 dBA
Electro Magnetic Compatibility - EN 62040-1, EN 62040-2, 62040-3, EN 60950-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5
Operating Temperature & Humidity - 0C~45C, Maximum 20~90% (Non Condensed)
Storage Temperature - -20C~70C
Protection Class - IP 20
Cooling Type - Forced Cooling Fan with Adjusted Speed
Operating Altitude - < 1000 meters (from Sea Level)
Dimensions (mm), W x H x D - 483 x 88 (2U) x 450
Weight, without / with Battery (kg) - 11.2 + 25.3