UPS ARTronic Titanium Plus, 3kVA/2.4kW, ON Line

id 4018 Код: UPS3KVATITANIUMPLUS
  • Модел: 3kVA Titanium Plus
  • Марка: Artronic
  • Изходяща мощност: 3000 VA
  • Тип: ON Line
  • Формфактор: Tower
  • Гаранция: 24 месеца
  • Наличност: Стар продукт
    ОписаниеХарактеристикиРевюта / Въпроси
    ARTon Titanium Plus
    On Line Uninterrupaible Power Supply

    - First Class Double Conversion Uninterruptable Power Supply
    - DSP Controlled High Reliability
    - Output Power Factor: 0.8
    - Graphic LCD Display and User Friendly Control Keys
    - Green Energy with Input Power Factor (PFC) > 0.99
    - 95% Efficiency with ECO Mode, 50/60 - 60/50 Running with Converter Mode
    - Emergency Power Off Function (EPO), Operating Temperature 0 ~ 45C
    - Ultra Wide Input Voltage Tolerance (110 ~ 300 VAC)
    - Short Recharge Time (5 hours) & Long Backup Options
    - Freee of Charge, Network Supported Monitoring & Control Software
    - SNMP & AS400 Network Monitoring Options
    - Silent & Economic Operation with Adjusted Fan Speed
    - Automatic Restart & Control Start Operation

    Capacity (VA/Watt) - 3000 VA / 2400 Watt

    Input-Rectifier

    Voltage-Voltage Tolerance - 220 VAC, 1 Phase + Neutral, 110 ~ 300 VAC

    Voltage Tolerance According to Load %
    Transfer to battery at 110 VAC for 0~60% load, 120 VAC for 61~70% load, 140 VAC for 71~80% load, 160 VAC for 81~100% load (Tolerance+/- 5V)
    Transfer to battery at 300 VAC for 0~100% load, transfer back to the mains at 285 VAC for 0~100% load

    Power Factor - >=0.99
    Current (maximum) - 12A
    Frequency - 46~54 Hz

    Output - Inverter & Bypass

    Power Factor - 0.8
    Voltage - Voltage Tolerance - 220 VAC +/-2%
    Dynamic Response - Maximum Deviation <= 6% AT 20-100% lOAD cHANGE, <=9% AT 0-100% lOAD cHANGE
    Correction Time - 100 mili seconds to be with in +/- 2% Static Tolerance at 0-100-0% Load Change
    Frequency - Frequency Tolerance - 50 Hz, +/- 0.2 Hz for Battery Operation
    Voltage Waveform - Pure Sine Wave
    Total Harmonic Distortion - <=3% at linear load
    Crest Factor - 3:1
    Overload Capacity - 30 seconds for 110-150%, 300 mili seconds for > 150% Over Load
    Short Circuit Protection - Electronic Short Circuit Protection
    Bypass & Transfer Time - Standard Static Bypass, 0 (zero) for Line Mode to Battery Mode, 2.5 mili seconds for Inverter to Bypass Mode
    Bypass Tolerance & Adjustment - 80 ~ 286 VAC Adjustable, Bypass can be Disabled or Enabled to Use in Standby Mode

    Battery

    Type & Placement - Maintenance Free Dry Type Battery, Internal or External Regarding to Demand
    Capacity & Quantity - 12V 7Ah x 8 pieces
    Backup Time (100% SMPS Load) - 6 minutes
    Float Charge Voltage - 110 +/- 0.4 VDC
    End of Discharge Voltage - 80 VDC
    Battery Charge Currenty & Charge Time - Standard 1 Amper Charge Current, 5 hours Charge Time to 90% Capacity After Discharge, Optional High Capacity Charger for Long Backup Demand

    Indications & Control panel

    Type - Graphic LCD Panel
    Control Panel - Touchpad Buttons (On/off, Audible Alarm Disable, Up/Down, Enter)
    Measurements & Warning - UPS Status, Input/Output Voltage & Frequency, Load %, Battery Capacity & Voltage, Warning & Alarm Messages
    Indications (LCD) - Mimic Diagram for Energy Flow, Measurements, Warnings, Faults, Adjustments ECO Mode, Converter Mode

    Protections

    Over Load - 60sn at 105%~110% Load, 30sn at 111%-125% Load, 10sn at 126%~150% Load, 1sn at 150% Load Transfer to Bypass Without Any Break After Over Load Period
    Short Circuit - Automatic Inverter Shutdown
    Over Temperature - Load Transfer to Bypass for 90C Internal Temperature, Transfer Back to Inverter When Internal Temperature < 80C
    Modem / Network Protection - Surge Protection for Modem / Network Line

    Audible Warnings

    Warning Type and Warnings
    Buzzer, Mutable with Audible Alarm Disable
    Different Audible Signals for Battery Operation, Battery Low Voltage, UPS Fault, Over Load

    Communications

    Interface & Protocol - Smart RS232 Communication with DB9 Port, Optional SNMP or AS400 Support
    Software - Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98/ME/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported

    General

    Efficiency - AC to AC at 100% / at ECO Mode - 88 % / 95 %
    Noise Level - < 50 dBA
    Electro Magnetic Compatibility - EN 62040-1, EN 62040-2, 62040-3, EN 60950-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5
    Operating Temperature & Humidity - 0~45C, Maximum 20~90 % (Non Condensed)
    Storage Temperature -20C~70C
    Protection Class - IP 20
    Cooling Type - Force Cooling Fan with Adjusted Speed
    Operating Altitude - < 1000 meters (from Sea Level)
    Dimensions (mm), W x H x D - 192 x 340 x 460
    Weight, without / with Battery (kg) - 16 / 35.5



    Виж още UPS Artronic
    Виж всички UPS в категорията
    Технически характеристики
    Изходяща мощност:  3000 VA
    Тип:  ON Line
    Формфактор:  Tower
    Добави Ревю / Въпрос
    Оцени продукта или задай въпрос?
    0.00 от 0 ревюта
    • 5
      0 ревюта
    • 4
      0 ревюта
    • 3
      0 ревюта
    • 2
      0 ревюта
    • 1
      0 ревюта
    • Какво пазаруват другите Какво пазаруват другите
    • Какво пазаруват другите Най-продавани продукти
    • Какво пазаруват другите Промоционални продукти
    prev slider image prev slider hover image next slider image next slider hover image

    ARTronic Titanium Plus 3kVA Tower
    prev slider image prev slider hover image
    • ARTronic Titanium Plus 3kVA Tower
    next slider image next slider hover image