Суич Ruijie RG-S5300-24GT4XS-E
НазадСуич Ruijie RG-S5300-24GT4XS-EСуич Ruijie RG-S5300-24GT4XS-EСуич Ruijie RG-S5300-24GT4XS-EСуич Ruijie RG-S5300-24GT4XS-EНапред

Суич Ruijie RG-S5300-24GT4XS-E, 336000 Mbps, 28 порта, 24x 10/100/1000M, 4x SFP+

id 258871 Код: NTLHRUIJIERGS530024GT4XSE
1282.78 лв

Всички цени са с начислен ДДС

ОписаниеХарактеристикиРевюта / ВъпросиВземи на изплащане

Ruijie RG-S5300-24GT4XS-E

Highlight Features

  • Rich port types, 24 x 1000 Mbps Ethernet ports, 4 x 10G optical ports for uplink
  • VSU virtualization, flexible networking and high performance
  • Network security policies and real-time monitoring, delivering enhanced network robustness
  • Abundant QoS policies for flexible resource allocation, making congestion a thing of the past
  • Multiple management modes, simplified and easy network maintenance

Specifications:

Interface specifications:

Fixed port

24 x 10/100/1000M auto-negotiation electrical ports, 4 x 1G/10G SFP+ ports

Power module

Built-in power module

Fixed management port

1 x MGMT port, 1 x console port, and 1 x USB port

System specifications:

Packet forwarding rate

96 Mpps/126 Mpps

System switching capacity

336 Gbps/3.36 Tbps

Number of MAC addresses

32,000

ARP table size

2,000

ND table size

1,000

Routing table size (IPv4/IPv6)

4000(IPv4/IPv6)

Number of ACEs

Ingress: 3,500, Egress: 1,500

Number of VSU members

4

Number of IGMP groups

2,500

Number of MLD groups

1,000

Number of VRFs

512

Dimensions (W x D x H)

442 mm x 220 mm x 43.6 mm (17.40 in. x 8.66 in. x 1.72 in.), 1 RU

CPU

1.2 GHz dual-core processor

Storage

Flash memory: 2, GBSDRAM: 1 GB

Power and Consumption

Maximum power consumption

< 40W

Rated input voltage

AC input: 100 V to 240 V

Frequency: 50/60 Hz

Maximum input voltage

AC input: 90 V to 264 V

MTBF> 200,000 hours

Primary airflowFront-to-rear airflow

Operating temperature

0°C to 45°C (32°F to 113°F) at an altitude in the range of 0 m to 1,800 m (5905.51 ft.)Altitude 1,800 m (5905.51 ft.) to 5,000 m (16404.20 ft.): The maximum temperature decreases by 1°C (1.8°F) each time the altitude increases by 220 m (721.78 ft.).

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

10% to 90% RH (non-condensing)

Storage humidity

5% to 90% RH (non-condensing)

Operating altitude

0 m to 5,000 m (16404.20 ft.)

Operating noise

40.9 dB at the temperature of 27°C (80.6°F)48.8 dB at the temperature of 45°C (113°F)

Interface surge protection

Communication port: 10 kV (common mode) (MGMT port: 4 kV)Power port: 6 kV (common/differential mode)

Software specifications:

Ethernet switching:

IEEE 802.1Q (supporting 4K VLANs)

Jumbo frame (maximum length: 9,216 bytes)

Maximum number of VLANs that can be created: 4,094

Voice VLAN

Super VLAN and private VLAN

MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment

GVRP

Basic QinQ and selective QinQ

STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)

Auto errdisable recoveryBPDU filterBPDU guardPort fastRoot guard

ERPS (G.8032 v1/v2), sing ring, tangent ring, intersecting ring, and load balancing

LLDP/LLDP-MED, LLDP IPv6, and LLDP-POE

MAC address filtering Setting the MAC address aging time

IP service

Static and dynamic ARP, ARP proxy, and ARP entry timeout

DHCP client, DHCP relay, DHCP server, and DHCP snooping

DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping

DNS client, DNS proxy, and DNSv6 client

Neighbor Discovery (ND), ND proxy, and ND snooping

IPv6 addressing, IPv6 ping, and IPv6 tracert

GRE tunnel

IP routing

IPv4 and IPv6 static routing

RIP and RIPng

OSPFv2 and OSPFv3

IS-ISv4 and IS-ISv6

BGP4 and BGP4+

Routing policy

IPv4/VRF

IPv4/IPv6 PBR

Multicast

IGMPv1/v2/v3

IGMPv1/v2 snooping

IGMP fast leavePIM-DM, PIM-SM, PIM-SSM, PIM SMv6, and PIM-SSMv6

MSDP for inter-domain multicast

MLDv1/v2 and MLD proxy

MLDv1/v2 snooping

PIM-SMv6

Multicast source IP address check

Multicast source port check

ACL and QoS

Standard IP ACLs (hardware ACLs based on IP addresses)

Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers)

Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type)

Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)

Time based ACLs, ACL 80, and IPv6 ACL

Global ACLs

ACL redirection

Port traffic identification

Port traffic rate limiting

802.1p/DSCP/ToS traffic classification

Congestion management: SP, WRR, DRR, WFQ, SP+WFQ, SP+WRR, SP+DRR, and SP+WFQ

Congestion avoidance: tail drop, RED, and WRED

Eight priority queues per port

Security

Multiple AAA modes

RADIUS

RADIUS and TACACS+

IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication

Web authentication

Hypertext Transfer Protocol Secure (HTTPS)

SSHv1 and SSHv2

Global IP-MAC binding

ICMP

Port security

IP source guard

SAVI

ARP spoofing prevention

CPP and NFPP

Multiple attack defense functions

3-tuple binding (IP address, MAC address, and port)

3-tuple binding (IPv6 address, MAC address, and port)

Filtering of invalid MAC addresses

Port- and MAC address-based 802.1X authentication

MAB authentication

Portal authentication and Portal 2.0 authentication

ARP check

DAI

ARP packet rate limiting

Gateway ARP spoofing prevention

Broadcast storm suppression

Hierarchical management of administrators and password protection

BPDU guard

Port protection

Reliability

REUP

RLDP, Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control

Data Link Detection Protocol (DLDP)

IPv4 VRRP v2/v3, IPv6 VRRP, and super-VLAN for VRRP

BFD, RAS, NSR, VRRR, VRRP+, and SDN loop detection

Link monitoring, fault notification, and remote loopback based on 802.3ah (EFM)

Device virtualization

VSU

Local and remote stacking

Inter-chassis link binding in a stack

Virtualization through standard service interfaces

NMS and maintenance

SPAN, RSPAN, and ERSPAN

sFlow

NTP client, NTP server, NTPv6 client, and NTPv6 server

SNTP

CLI (Telnet/Console)

FTP client, FTP server, FTPv6 client, and FTPv6 server

TFTP client, TFTP server, TFTPv6 client, and TFTPv6 server

FTP and TFTP

SNMP v1/v2c/c3

Web

Syslog/Debugging

RMON (1, 2, 3, 9)Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, as well as private alarm extension groupsRMON used to implement Ethernet statistics, historical statistics, and alarm functions

NETCONF

MACC

CWMP

gRPC

OpenFlow Special 1.3Flow table analysis defined by all protocolsTransmission of specified packets to the controllerConfiguring the controller's IP address and portNotifying port status changes to the controller

RNS, configuration rollback, and 802.3ah

IETF

RFC 1058 Routing Information Protocol (RIP)

RFC 1157 A Simple Network Management Protocol (SNMP)

RFC 1305 Network Time Protocol Version 3 (NTP)

RFC 1349 Internet Protocol (IP)

RFC 1350 TFTP Protocol (revision 2)

RFC 1519 CIDR

RFC 1583 OSPF Version 2

RFC 1591 Domain Name System Structure and Delegation

RFC 1643 Ethernet Interface MIB

RFC 1757 Remote Network Monitoring (RMON)

RFC 1812 Requirements for IP Version 4 Router

RFC 1901 Introduction to Community-based SNMPv2

RFC 1902-1907 SNMP v2

RFC 1918 Address Allocation for Private Internet

RFC 1981 Path MTU Discovery for IP version 6

RFC 1997 BGP Communities Attribute

RFC 2131 Dynamic Host Configuration Protocol (DHCP)

RFC 2132 DHCP Options and BOOTP Vendor Extensions

RFC 2236 IGMP

RFC 2328 OSPF Version 2

RFC 2385 Protection of BGP Sessions via the TCP MD5 Signature Option

RFC 2439 BGP Route Flap Damping

RFC 2460 Internet Protocol, Version 6 (IPv6)

RFC 2461 Neighbor Discovery for IP Version 6 (IPv6)

RFC 2462 IPv6 Stateless Address Auto configuration

RFC 2463 Internet Control Message Protocol for IPv6 (ICMPv6)

RFC 2545 Use of BGP 4 Multiprotocol Extensions for IPv6 Inter Domain Routing

RFC 2571 SNMP Management Frameworks

RFC 2711 IPv6 Router Alert Option

RFC 2787 Definitions of Managed Objects for the Virtual Router Redundancy Protocol

RFC 2863 The Interfaces Group MIB

RFC 2865 Remote Authentication Dial In User Service (RADIUS)

RFC 2918 Route Refresh Capability for BGP 4

RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only)

RFC 2934 Protocol Independent Multicast MIB for IPv4

RFC 3046 DHCP Option82

RFC 3065 Autonomous System Confederation for BGP

RFC 3101 OSPF Not so stubby area option

RFC 3137 OSPF Stub Router Advertisement sFlow

RFC 3417 (SNMP Transport Mappings)

RFC 3418 Management Information Base (MIB) for the Simple Network Management Protocol (SNMP)

RFC 3509 Alternative Implementations of OSPF Area Border Routers

RFC 3513 IP Version 6 Addressing Architecture

RFC 3575 IANA Considerations for RADIUS

RFC 3579 RADIUS Support For EAP

RFC 3623 Graceful OSPF Restart

RFC 3768 VRRP

RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6

RFC 3973 PIM Dense Mode

RFC 4022 MIB for TCP

RFC 4271 A Border Gateway Protocol 4 (BGP 4)

RFC 4273 Definitions of Managed Objects for BGP 4

RFC 4360 BGP Extended Communities Attribute

RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP)

RFC 4486 Subcodes for BGP Cease Notification Message

RFC 4552 Authentication/Confidentiality for OSPFv3

RFC 4724 Graceful Restart Mechanism for BGP

RFC 4750 OSPFv2 MIB partial support no SetMIB

RFC 4760 Multiprotocol Extensions for BGP 4

RFC 4940 IANA Considerations for OSPF

RFC 5065 Autonomous System Confederation for BGP

RFC 5187 OSPFv3 Graceful Restart

RFC 5340 OSPFv3 for IPv6

RFC 5492 Capabilities Advertisement with BGP 4

RFC 6620 FCFS SAVI

RFC 768 User Datagram Protocol (UDP)

RFC 783 TFTP Protocol (revision 2)

RFC 792 Internet Control Message Protocol (ICMP)

RFC 793 Transmission Control Protocol (TCP)

RFC 813 Window and Acknowledgement Strategy in TCP

RFC 815 IP datagram reassembly algorithms

RFC 826 Ethernet Address Resolution Protocol (ARP)

RFC 854 Telnet Protocol

RFC 959 File Transfer Protocol (FTP)

IEEE

IEEE 802.2 Logical Link Control

IEEE 802.1ab Link Layer Discovery Protocol

IEEE 802.1ad Provider Bridges

IEEE 802.1ax/

IEEE802.3ad Link Aggregation

IEEE 802.1D Media Access Control (MAC) Bridges

IEEE 802.1D Spanning Tree Protocol

IEEE 802.1Q Virtual Bridged Local Area Networks (VLAN)

IEEE 802.1s Multiple Spanning Tree Protocol

IEEE 802.1w Rapid Spanning Tree Protocol

IEEE 802.3ad Link Aggregation Control Protocol (LACP)

IEEE 802.3bt Power over Ethernet

IEEE Std 802.3x Full Duplex and flow control





Виж още Суич Ruijie
Виж всички продукти Суич в категорията

Технически характеристики

Брой портове:  28
Максимална скорост:  10 Mbps
Стандарт:  802.3bt
Управляем:  Да

Добави Ревю / Въпрос

Оцени продукта или задай въпрос?

0.00 от 0 ревюта
  • 5
    0 ревюта
  • 4
    0 ревюта
  • 3
    0 ревюта
  • 2
    0 ревюта
  • 1
    0 ревюта

Вземи на изплащане

BNP Paribas
BNP Paribas
TBI logo
  • Какво пазаруват другите Какво пазаруват другите
  • Какво пазаруват другите Най-продавани продукти
  • Какво пазаруват другите Промоционални продукти

Свързани продукти и тагове:


Суич Ruijie RG-S5300-24GT4XS-E
  • Суич Ruijie RG-S5300-24GT4XS-E
  • Суич Ruijie RG-S5300-24GT4XS-E
  • Суич Ruijie RG-S5300-24GT4XS-E
  • Суич Ruijie RG-S5300-24GT4XS-E
  • Суич Ruijie RG-S5300-24GT4XS-E