• High Frequency and True Double-Conversion
• DSP Digital Control Technology
• Input Power Factor Correction (PFC)
• Wide Input Voltage Range (110V-300V)
• Output Power Factor 0.9
• Cold Start
• Frequency Adaptive
• ECO Mode Operation for Energy Saving
• Selectable Output Voltage Via LCD
• Output Bypass Settable Via LCD
• Selectable Battery Low Voltage Via LCD
• Automatically Diagnose When Starts
• Advanced Battery Management (ABM)
• Short Circuit and Overload Protection
• Automatically Charging Battery at UPS Off Mode
• Fan Speed Auto Control When Load Varies
• Standard RS232 Communication Port and RJ45 Protection
Login
input Voltage 208V / 220V / 230V / 240VAC
Operating Voltage Range 50% load (110-300) VAC ± 5, at full load (160-300) ± 5 VAC
Operating Frequency Range 40 / 70Hz (auto-sensing)
Power factor ≥0.98
Bypass Voltage Range Nominal output voltage - 34V ~ + 32V nominal output voltage
Bypass Frequency Range 55-65Hz 45-55Hz or ± 1%
harmonic Distortion ≤ 3%
ECO Range 208V / 220V / 230V / 240VAC ± 10%
Generator Compatible
Exit
Output Voltage 208V / 220V / 230V / 240VAC (selectable) ± 5%
Power factor 0.9
Voltage Regulation ± 1%
Frequency 45-55Hz or 55-65Hz ± 6% (Network Mode), 50-60 Hz ± 0.2% (battery mode)
Waveform Pure Sine Wave
Crest Factor 3: 1
harmonic Distortion ≤ 2% (linear load)
≤ 5% (Non-Linear Load)
Transfer Time AC mode to Battery Mode: 0ms, Inverter - Bypass Mode 4ms (Typical)
Excess Capacity Network Mode 105% - 150%: 30s after bypass Transfer,
Bypass Mode > 150%: 300ms after bypass Transfer
parallel Operation N / A
Yield
Inverter Mode ≥ 90%
Battery Mode ≥ 87%
ECO Mode ≥ 94%
Battery
Battery Voltage 72 VDC
Standard Model Internal Battery 6 x 12V 9Ah
Charging Current The standard Model 1 A
Prolonged Model 6a
Typical Recharge Time 4 hours (90% capacity)
Protection
full Protection Overload, Short Circuit and Smart Battery Charge-Discharge Protection
System Specifications
Charging Current Smart Charging System
overheating Compatible
Intelligent Alarm System Compatible
LED & LCD Display Compatible
Alarm
Network Failure 4 sec cycle with buzzer
Low Battery Voltage 1 sec cycle with buzzer
Overload beep twice in 1 sec intervals
UPS Fault Continuous beep
physical Features
Dimensions (WxDxH) (mm) 190 x 452 x 341
Package Dimensions (WxDxH) (mm) 320 x 550 x 462
Net Weight (kg) 26.6
Gross Weight (kg) 28.8
Translated to Terms
Operating temperature 0 ~ 40 ° C
Storage Temperature -20 ° C ~ 55 ° C
Battery Operating Temperature -10ºC ~ + 50ºC
Relative humidity 20 ~ 90% RH @ 0 ~ 40 ° C (non-condensing)
Noise Level ≤ 45dB (1m)
Governance
Communication Interface Standard RS232, optional USB-SNMP
Software Windows 98/2000/2003 / XP / Vista / 2008 / Windosws Supports 7/8
Emergency Shutdown Optional
standards
Security CE LVD
EMC CE EMC
Виж още UPS Makelsan
Виж всички UPS в категорията
• DSP Digital Control Technology
• Input Power Factor Correction (PFC)
• Wide Input Voltage Range (110V-300V)
• Output Power Factor 0.9
• Cold Start
• Frequency Adaptive
• ECO Mode Operation for Energy Saving
• Selectable Output Voltage Via LCD
• Output Bypass Settable Via LCD
• Selectable Battery Low Voltage Via LCD
• Automatically Diagnose When Starts
• Advanced Battery Management (ABM)
• Short Circuit and Overload Protection
• Automatically Charging Battery at UPS Off Mode
• Fan Speed Auto Control When Load Varies
• Standard RS232 Communication Port and RJ45 Protection
Login
input Voltage 208V / 220V / 230V / 240VAC
Operating Voltage Range 50% load (110-300) VAC ± 5, at full load (160-300) ± 5 VAC
Operating Frequency Range 40 / 70Hz (auto-sensing)
Power factor ≥0.98
Bypass Voltage Range Nominal output voltage - 34V ~ + 32V nominal output voltage
Bypass Frequency Range 55-65Hz 45-55Hz or ± 1%
harmonic Distortion ≤ 3%
ECO Range 208V / 220V / 230V / 240VAC ± 10%
Generator Compatible
Exit
Output Voltage 208V / 220V / 230V / 240VAC (selectable) ± 5%
Power factor 0.9
Voltage Regulation ± 1%
Frequency 45-55Hz or 55-65Hz ± 6% (Network Mode), 50-60 Hz ± 0.2% (battery mode)
Waveform Pure Sine Wave
Crest Factor 3: 1
harmonic Distortion ≤ 2% (linear load)
≤ 5% (Non-Linear Load)
Transfer Time AC mode to Battery Mode: 0ms, Inverter - Bypass Mode 4ms (Typical)
Excess Capacity Network Mode 105% - 150%: 30s after bypass Transfer,
Bypass Mode > 150%: 300ms after bypass Transfer
parallel Operation N / A
Yield
Inverter Mode ≥ 90%
Battery Mode ≥ 87%
ECO Mode ≥ 94%
Battery
Battery Voltage 72 VDC
Standard Model Internal Battery 6 x 12V 9Ah
Charging Current The standard Model 1 A
Prolonged Model 6a
Typical Recharge Time 4 hours (90% capacity)
Protection
full Protection Overload, Short Circuit and Smart Battery Charge-Discharge Protection
System Specifications
Charging Current Smart Charging System
overheating Compatible
Intelligent Alarm System Compatible
LED & LCD Display Compatible
Alarm
Network Failure 4 sec cycle with buzzer
Low Battery Voltage 1 sec cycle with buzzer
Overload beep twice in 1 sec intervals
UPS Fault Continuous beep
physical Features
Dimensions (WxDxH) (mm) 190 x 452 x 341
Package Dimensions (WxDxH) (mm) 320 x 550 x 462
Net Weight (kg) 26.6
Gross Weight (kg) 28.8
Translated to Terms
Operating temperature 0 ~ 40 ° C
Storage Temperature -20 ° C ~ 55 ° C
Battery Operating Temperature -10ºC ~ + 50ºC
Relative humidity 20 ~ 90% RH @ 0 ~ 40 ° C (non-condensing)
Noise Level ≤ 45dB (1m)
Governance
Communication Interface Standard RS232, optional USB-SNMP
Software Windows 98/2000/2003 / XP / Vista / 2008 / Windosws Supports 7/8
Emergency Shutdown Optional
standards
Security CE LVD
EMC CE EMC
Виж още UPS Makelsan
Виж всички UPS в категорията
Технически характеристики
Изходяща мощност: | 3000 VA |
---|---|
Тип: | ON Line |
Формфактор: | Tower |
Добави Ревю / Въпрос
Оцени продукта или задай въпрос?
0.00 от 0 ревюта
- 5
- 4
- 3
- 2
- 1
Свързани продукти
-
UPS PowerWalker DC SecureAdapter 10120431, 12VA/12W, малък UPS за устройства на 12V(рутери/декодери/IP камери), 2600 mAh Li-Ion батерия, до 3 часа поддръжка
60.61лв
-
UPS Repotec 800DU 800VA/480W, AVR, USB, Line Interactive
94.03лв
-
UPS Njoy Keen 600 UPLI-LI060KU-CG01B, 600VA/360W, Line Interactive, Tower
105.00лв