TUNCMATIK NEWTECH PRO II X9 1K
TSK5303
General Properties
Product Code: TSK5303
EAN Code: 8697842805539
Series description: Newtech Pro II
Product description: Newtech Pro II 1 kVA
Capacity / Power: 1 kVA / 900 W
Display: LCD Panel
Alarm: Battery mode, Low battery, Over load, Error
Input
Nominal voltage: 200 / 208 / 220 / 230 / 240 VAC
Voltage range Low voltage transfer: @100%-80% load 160 VAC ±5%, @80%-70% load 140 VAC ±5%, @70%-60% load 120 VAC ±5%, @60%-0% load 110 VAC ±5%, (<35°C)
Voltage range Low voltage back transfer: @100%-80% load 175 VAC ±5%, @80%-70% load 155 VAC ±5%, @70%-60% load 135 VAC ±5%, @60%-0% load 125 VAC ±5%, (<35°C)
Voltage range High voltage transfer: 300 VAC ± 5%
Voltage range High voltage back transfer: 290 VAC ± 5%
Frequency range: 40 Hz ~ 70 Hz
Power factor: @100% load 0.990 (Nominal input voltage)
Bypass voltage range: Bypass high voltage point 200/208/220/230/240 VAC output models
Bypass voltage range: Bypass high voltage point 200/208/220/230/240 VAC output models
Phase: Single phase + Ground
Output
Voltage: 200 / 208 / 220 / 230 / 240 VAC
Output power factor (PF): 0.9
AC voltage regulation (Battery mode): ± 1%
Frequency range (Synchronized): 47 Hz ~ 53 Hz or 57 Hz ~ 63 Hz
Frequency range (Battery mode): 50 Hz or 60 Hz ± 0.1 Hz
Overload Line mode: 105-110% transfer to by-pass in 10min, 110-130% transfer to by-pass in 1min, 130-150% transfer to by-pass in 3sec
Overload Battery mode: 105-110% transfer to by-pass in 1min, >110% transfer to by-pass in 3sec
Current crest ratio: 3/1 max
Harmonic distortion: ≤3% THD (linear load) ≤6% THD (non-linear load)
Transfer time Line <-> Battery: 0 msec
Transfer time Inverter <-> By-pass: 4 msec (typical)
Waveform (Battery mode): Pure sinewave
Efficiency
Line mode: ~ 88%
Battery mode: ~ 83%
Battery
Type of battery: 12V9AH
Number of battery: 2
Charge time: Depends on external battery capacity
Charge voltage: 27.4 VDC
Charge current: 1A
Indicators & Alarm
LCD Panel: UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions
Alarm: Battery mode, Low battery, Overload, Fault
Dimensions & Weight
D x W x H (mm): 293 x 144 x 209
Net weight (kg): 8.9
Environmental
Operating temperature: 0-40°C
Humidity: 20-90% RH (non-condensing)
Noise level (audible): < 50 dBA, from 1m
Management
Smart RS-232 or USB: Windows 98/2000/2003/XP/Vista/2008, Windows 7/8, Linux, MAC
SNMP (Optional): Power management from SNMP manager and web browser
Виж още UPS Tuncmatik
Виж всички UPS в категорията
TSK5303
General Properties
Product Code: TSK5303
EAN Code: 8697842805539
Series description: Newtech Pro II
Product description: Newtech Pro II 1 kVA
Capacity / Power: 1 kVA / 900 W
Display: LCD Panel
Alarm: Battery mode, Low battery, Over load, Error
Input
Nominal voltage: 200 / 208 / 220 / 230 / 240 VAC
Voltage range Low voltage transfer: @100%-80% load 160 VAC ±5%, @80%-70% load 140 VAC ±5%, @70%-60% load 120 VAC ±5%, @60%-0% load 110 VAC ±5%, (<35°C)
Voltage range Low voltage back transfer: @100%-80% load 175 VAC ±5%, @80%-70% load 155 VAC ±5%, @70%-60% load 135 VAC ±5%, @60%-0% load 125 VAC ±5%, (<35°C)
Voltage range High voltage transfer: 300 VAC ± 5%
Voltage range High voltage back transfer: 290 VAC ± 5%
Frequency range: 40 Hz ~ 70 Hz
Power factor: @100% load 0.990 (Nominal input voltage)
Bypass voltage range: Bypass high voltage point 200/208/220/230/240 VAC output models
Bypass voltage range: Bypass high voltage point 200/208/220/230/240 VAC output models
Phase: Single phase + Ground
Output
Voltage: 200 / 208 / 220 / 230 / 240 VAC
Output power factor (PF): 0.9
AC voltage regulation (Battery mode): ± 1%
Frequency range (Synchronized): 47 Hz ~ 53 Hz or 57 Hz ~ 63 Hz
Frequency range (Battery mode): 50 Hz or 60 Hz ± 0.1 Hz
Overload Line mode: 105-110% transfer to by-pass in 10min, 110-130% transfer to by-pass in 1min, 130-150% transfer to by-pass in 3sec
Overload Battery mode: 105-110% transfer to by-pass in 1min, >110% transfer to by-pass in 3sec
Current crest ratio: 3/1 max
Harmonic distortion: ≤3% THD (linear load) ≤6% THD (non-linear load)
Transfer time Line <-> Battery: 0 msec
Transfer time Inverter <-> By-pass: 4 msec (typical)
Waveform (Battery mode): Pure sinewave
Efficiency
Line mode: ~ 88%
Battery mode: ~ 83%
Battery
Type of battery: 12V9AH
Number of battery: 2
Charge time: Depends on external battery capacity
Charge voltage: 27.4 VDC
Charge current: 1A
Indicators & Alarm
LCD Panel: UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions
Alarm: Battery mode, Low battery, Overload, Fault
Dimensions & Weight
D x W x H (mm): 293 x 144 x 209
Net weight (kg): 8.9
Environmental
Operating temperature: 0-40°C
Humidity: 20-90% RH (non-condensing)
Noise level (audible): < 50 dBA, from 1m
Management
Smart RS-232 or USB: Windows 98/2000/2003/XP/Vista/2008, Windows 7/8, Linux, MAC
SNMP (Optional): Power management from SNMP manager and web browser