Makelsan MU10000N11DT004
Input
Voltage Range 176 ±5VAC~276 ±5VAC
Frequency Range 46~54Hz ±0.5Hz or 56~64Hz ±0.5Hz Auto Sensing
Phase Single Phase
Power Factor ≥0.98
Output
Voltage Range 220/230Vac ±1%
Phase Single Phase
Frequency Range Synchronized With the Utility on AC Mode; 50Hz/60Hz ±0.2% On Battery Mode
THD (Linear Load) <2%
THD (Non-Linear Load) <6%
Overload Capability 105%~130%, 10min Turn To Bypass Mode; >130% 1s Turn to Bypass Mode
Crest Factor 3:1 (max)
Short Circuit Protection
5 Cycles Turn off Inverter, Not Transfer to Bypass, Provide Alarm (AC Mode)
5 Cycles Turn off Inverter, Provide Alarm (Battery Mode)
Input Fuse Blown or Breaker Action (Bypass Mode)
Waveform Pure Sine Wave
Transfer Time 0ms
Efficiency ≥88%
Battery
Model 12V Sealed Lead Acid Maintenance Free
DC Voltage 240V DC
Configuration 20×12V/7AH
Backup Time (Half Load) 20min 13min
Backup Time (Full Load) 7min 5min
Charge Current (Standard Unit) 1A
Charge Current (Long Time Unit) 5A
Recharge Time 90% Capacity After 8hrs Charging
Communication Interface
Parallel Port Parallel Availability For Redundancy And Load Sharing up to Three Units
LCD Indication
1.Input Voltage / Frequency, Battery Voltage, Output Voltage / Frequency, Load Watt/VA Value and Percent, Inverter Temperature
2.Operation Mode Such as “On-line”, “On batt”, or “On bypass”
LED Indication
1. Green LED for Normal Operation,
2. Yellow LED for Warning Condition,
3. Red LED For Abnormal Operation
Noise Level <55dB
Environment
Temperature 0~40°C
Humidity 0%~95% (Non-Condensing)
Altitude <1500m
Storage Temperature -40~50°C
Виж още UPS Makelsan
Виж всички UPS в категорията
Input
Voltage Range 176 ±5VAC~276 ±5VAC
Frequency Range 46~54Hz ±0.5Hz or 56~64Hz ±0.5Hz Auto Sensing
Phase Single Phase
Power Factor ≥0.98
Output
Voltage Range 220/230Vac ±1%
Phase Single Phase
Frequency Range Synchronized With the Utility on AC Mode; 50Hz/60Hz ±0.2% On Battery Mode
THD (Linear Load) <2%
THD (Non-Linear Load) <6%
Overload Capability 105%~130%, 10min Turn To Bypass Mode; >130% 1s Turn to Bypass Mode
Crest Factor 3:1 (max)
Short Circuit Protection
5 Cycles Turn off Inverter, Not Transfer to Bypass, Provide Alarm (AC Mode)
5 Cycles Turn off Inverter, Provide Alarm (Battery Mode)
Input Fuse Blown or Breaker Action (Bypass Mode)
Waveform Pure Sine Wave
Transfer Time 0ms
Efficiency ≥88%
Battery
Model 12V Sealed Lead Acid Maintenance Free
DC Voltage 240V DC
Configuration 20×12V/7AH
Backup Time (Half Load) 20min 13min
Backup Time (Full Load) 7min 5min
Charge Current (Standard Unit) 1A
Charge Current (Long Time Unit) 5A
Recharge Time 90% Capacity After 8hrs Charging
Communication Interface
Parallel Port Parallel Availability For Redundancy And Load Sharing up to Three Units
LCD Indication
1.Input Voltage / Frequency, Battery Voltage, Output Voltage / Frequency, Load Watt/VA Value and Percent, Inverter Temperature
2.Operation Mode Such as “On-line”, “On batt”, or “On bypass”
LED Indication
1. Green LED for Normal Operation,
2. Yellow LED for Warning Condition,
3. Red LED For Abnormal Operation
Noise Level <55dB
Environment
Temperature 0~40°C
Humidity 0%~95% (Non-Condensing)
Altitude <1500m
Storage Temperature -40~50°C